University of East Anglia – Lasdun Wall

Independent Design Checks and Structural Assessments for a Listed Building Refurbishment

Published: 17/11/2026 13:31

Richter supported the Mace Group with structural assessments and Category 3 design checks during the conservation and refurbishment of Building 3 of the Grade II listed Lasdun Wall at the University of East Anglia (UEA).

The project involved the extensive redevelopment of the existing concrete building to provide modern research laboratories, teaching facilities and associated building services. The works required significant alterations, including the removal and replacement of structural elements, while maintaining stability throughout construction.

Richter's Independent Design Checks covered items such as façade scaffolding, hoist foundations and the site tower crane bases.

However, the most challenging check was of a temporary propping design required to provide the building with temporary lateral stability whilst the existing concrete shear walls were removed and replaced with a new structure.

The challenge extended beyond checking the temporary bracing components. Richter also needed to verify how loads would transfer through the existing slabs, beams, columns and foundations during the temporary construction condition.

To assess this interaction, Richter developed a detailed 3D structural model incorporating both the existing building and the proposed temporary bracing system. The model enabled the behaviour of the combined structure to be assessed under a range of loading conditions, providing independent verification of the temporary works and their interaction with the permanent structure.

The available information on the concrete structure (including foundations) was limited. Richter used available archive information, site observations and ferrous reinforcement scanning to inform assessments.

Other structural assessments included verifying the capacity of existing concrete slabs and buried service tunnels to support heavy construction plant and checking excavation support adjacent to existing foundations.

By establishing where existing structural elements could safely accommodate the temporary loads, Richter was able to help minimise unnecessary strengthening and additional temporary works.

Richter's involvement provided independent engineering assurance across multiple stages of construction, supporting the safe refurbishment of the listed building while helping retain and make effective use of its existing structure.


 

Join Our Community

Join us to engineer a better world. Enter your email address to receive updates on our progress.